MTB 系列型号后缀 W R 表示水冷机器人装配型。水冷枪颈内部走循环冷却水,把导电嘴座与枪颈本体一起带走热量,因此在 350 A 以上的连续焊、厚板多层多道以及铝焊这类热输入敏感的场景里,水冷枪颈的易损件寿命明显更长。
代价是枪颈截面更大、重量更高,而且必须接冷却水循环,流量与水温不达标时会先烧导电嘴座,再烧枪颈本体。已经在用气冷枪的工位,改成水冷之前先确认水箱余量与管路接口,这一环节漏了,新枪颈上去一周就废。
| 枪型 | 枪颈角度 | L mm | H mm | 标准型 | OVT 型 | TXi 型 | TXM 型 |
|---|---|---|---|---|---|---|---|
| MTB 250i W R | 22° | 241 | 50 | 44,0350,3486 | 44,0350,3486,630 | 44,0350,3486,636 | 44,0350,3486,637 |
| MTB 250i W R | 22° | 383 | 50 | — | 44,0350,4299,630 | — | — |
| MTB 250i W R | 36° | 224 | 86 | 44,0350,3487 | 44,0350,3487,630 | 44,0350,3487,636 | 44,0350,3487,637 |
| MTB 250i W R | 36° | 366 | 86 | — | 44,0350,4300,630 | — | — |
| MTB 250i W R | 45° | 209 | 107 | 44,0350,3488 | 44,0350,3488,630 | 44,0350,3488,636 | 44,0350,3488,637 |
| MTB 250i W R | 45° | 351 | 107 | — | 44,0350,4301,630 | — | — |
| MTB 330i W R | 22° | 246 | 27 | 44,0350,3683 | 44,0350,3683,630 | 44,0350,3683,636 | 44,0350,3683,637 |
| MTB 330i W R | 22° | 331 | 27 | — | 44,0350,4228,630 | — | — |
| MTB 330i W R | 36° | 236 | 44.5 | 44,0350,3684 | 44,0350,3684,630 | 44,0350,3684,636 | 44,0350,3684,637 |
| MTB 330i W R | 36° | 321 | 44.5 | — | 44,0350,4229,630 | — | — |
| MTB 330i W R | 45° | 228.5 | 56.5 | 44,0350,3685 | 44,0350,3685,630 | 44,0350,3685,636 | 44,0350,3685,637 |
| MTB 330i W R | 45° | 313.5 | 56.5 | — | 44,0350,4230,630 | — | — |
| MTB 330i W R | 60° | 212.5 | 71 | 44,0350,3686 | 44,0350,3686,630 | 44,0350,3686,636 | 44,0350,3686,637 |
| MTB 330i W R | 60° | 297.5 | 71 | — | 44,0350,4231,630 | — | — |
| MTB 400i W R | 22° | 241 | 50 | 44,0350,3490 | 44,0350,3490,630 | 44,0350,3490,636 | 44,0350,3490,637 |
| MTB 400i W R | 36° | 224 | 86 | 44,0350,3491 | 44,0350,3491,630 | 44,0350,3491,636 | 44,0350,3491,637 |
| MTB 400i W R | 45° | 209 | 107 | 44,0350,3492 | 44,0350,3492,630 | 44,0350,3492,636 | 44,0350,3492,637 |
| MTB 500i W R | 22° | 241 | 50 | 44,0350,3494 | 44,0350,3494,630 | 44,0350,3494,636 | 44,0350,3494,637 |
| MTB 500i W R | 22° | 383 | 50 | — | 44,0350,4302,630 | — | — |
| MTB 500i W R | 36° | 224 | 86 | 44,0350,3495 | 44,0350,3495,630 | 44,0350,3495,636 | 44,0350,3495,637 |
| MTB 500i W R | 36° | 366 | 86 | — | 44,0350,4303,630 | — | — |
| MTB 500i W R | 45° | 209 | 107 | 44,0350,3496 | 44,0350,3496,630 | 44,0350,3496,636 | 44,0350,3496,637 |
| MTB 500i W R | 45° | 351 | 107 | — | 44,0350,4304,630 | — | — |
| MTB 700i W R | 22° | 241 | 50 | 44,0350,3657 | 44,0350,3657,630 | 44,0350,3657,636 | 44,0350,3657,637 |
| MTB 700i W R | 36° | 224 | 86 | 44,0350,3658 | 44,0350,3658,630 | 44,0350,3658,636 | 44,0350,3658,637 |
| MTB 700i W R | 45° | 209 | 107 | 44,0350,3659 | 44,0350,3659,630 | 44,0350,3659,636 | 44,0350,3659,637 |
250i 与 400i、500i 的枪颈几何完全一致(22° 为 241 mm,36° 为 224 mm,45° 为 209 mm),差别在枪颈内孔与冷却流道,因此外形看着一样、编码却是两套,这也是这类枪最容易配错的地方——不能按外形长度去猜型号。
330i 是唯一的例外:它的枪颈更短更细(22° 只有 246 mm,H 值为 27 mm),并且多出一个 60° 角度,用于立焊、横焊与狭窄立角。700i 则只做 22°、36°、45° 三个常规角度,没有加长行,需要更远的可达性时应当换用带加长枪颈的其他枪型,而不是在 700i 上硬接。
表中 L 值比标准行大 120 mm 到 142 mm 的行属于加长枪颈,一律只有 OVT 一列有订货号。加长枪颈的刚性下降,长时间焊接时容易在根部产生微变形,建议配合导丝校直装置使用,并在点检表里增加枪颈直线度检查项。
制式列(标准型 / OVT / TXi / TXM)决定易损件接口,四列之间不可互换。本页共 74 个订货号,覆盖五款水冷枪型的全部常规与加长变体,配图为系列示意,不对应任一条目的实物外观。